Total Station CalibrationPrescience Calibration Pvt Ltd. is ISO/ IEC 17025 : 2017 accredited calibration laboratory (NABL Accreditation). Prescience Calibration follow International standards to ensure good quality of calibration. This implies a high level of technical competence and well documented, traceable, calibration activity. It is thus assured that the calibration services offered are in compliance with ISO 9000 and IATF 16949 and any other standard as applicable. Laboratory also offers on-site calibration services.


Total Station CalibrationPrescience Calibration also offers surveying instrument calibration like Optical Level Calibration, Theodolite Calibration, Total station Calibration, Line Laser Calibration, Point Laser Calibration and Rotation Laser Calibration which are used in construction and survey. Electronic Theodolite Calibraton and Total Station Calibration are being carried out under laboratory conditions with high masters device of high accuracy traceable to National standard.


Total Station CalibrationPrescience Calibration uses master of high accuracy for horizontal and vertical angle calibration. Masters used for calibration are calibrated at National Physical Laboratory, New Delhi, India. Hence measurements are traceable to National standard Total Station Calibration are as per NABL accreditation.


What is Total Station

A total station is an optical instrument with built in electronic to measure horizontal and vertical angle, it is also integrated with electronic distance measurement (EDM), it has on-board memory and option for computer interface to collect stored data.


Prescience Calibration is NABL accredited calibration laboratory for calibration of Total Station.

Total Station Calibration

CST Berger Total Station Calibration

Why ISO 17025 accredited Total Station calibration services

ISO 17025 accreditation give formal recognition of competence to a Total Station calibration laboratory by certification agency in accordance to international standard, in India certification for ISO 17025 is provided by NABL.


Total Station being calibrated by ISO 17025 accredited calibration laboratory has many benefits which customer can get. ISO 17025 accredited Total Station Calibration laboratory is better controlled, and have Quality assurance system and technical competence to calibrate Total Station.


Total Station Customers have further benefit of recognition of such Total Station Calibration certificate in domestic and international market.


Which is better ISO 9000 or ISO 17025 accredited Total Station calibration services

In a nutshell ISO 9000 is quality management system describing all the document requirements. ISO 17025 apart from describing all the quality management system document requirement it also describes the technical requirements, all calibration laboratory follow ISO 17025 system of international standard. Total Station calibration is conducted by ISO 17025 accredited laboratory.


What is two peg test method used for Total Station certification

Two peg test method for Total Station is an outdoor test procedure, where error due to environmental condition like temperature and humidity cannot be controlled. Further error due to reflection and refraction cannot be avoided. Two peg test method also cannot provide measurement traceability. Hence precision Instruments like Total Station to be calibrated in calibration laboratory.


Can rent Total Station be used

Rented Total Station is being used by different user daily, as a result Total Station can get disturbed from is set point, under a situation where Total Station has to be used on rent, the calibration interval has to be shorter. Total Station calibration interval depends of type of user who have handled it. With the usage of control chart quality of Total Station can be determined along with frequency of Calibration.